The internal wiring for Three point starter is shown in the fig below. The three terminals of the starter are marked A, F and L. One line is directly connected to point L which is further connected to the starting handle (arm) through the overload release. If motor has to be started, we need to […]
Shunt Motor Starter
Four Point Starter
Four point starter is connected to a long-shunt compound motor. If we compare it to the generally used 3 point starter, we can easily mark one remarkable difference than its counterpart. In four point starter, the most critical ‘Hold ON coil’ (electromagnet) is placed out of the shunt field circuit. Rather to its place in […]